Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/1413 3-90-436168i
#5 Installing into an existing replace chimney (Figure
4.5) w/Full Liner
Thismethodprovidesexcellentventingfornormaloperation.
This method also provides natural draft in the event of a
powerfailure.
InsomeplacesintheUSandCanadaitisrequiredthatthe
ventpipeextendallthewaytothetopofthechimney.The
pipeorlinerinsidethechimneyshouldbe4"diameter.
Inthismethodacapshouldalsobeinstalledonthechimney
tokeepoutrain.Besuretouseapprovedpelletventpipe
ttings. Seal pipe joints with silicone or aluminum tape in
additiontothesealingsystemusedbythemanufacturer.Pipe
sizeshouldbeincreasedto4"usingthismethod.
#6 Installing into an existing chimney
(Figure 4.6) w/Full liner
Thismethodprovidesexcellentventingfornormaloperation.
This method also provides natural draft in the event of a
powerfailure.
InsomeplacesintheUSandCanadaitisrequiredthatthe
ventpipeextendallthewaytothetopofthechimney.Seal
pipejointswithsiliconeoraluminumtapeinadditiontothe
sealingsystemusedbythemanufacturer.Thepipeorliner
insidethechimneyshouldbe4"diameter.
Inthismethodacapshouldalsobeinstalledonthechimney
tokeepoutrain.
Figure 4.5