Revision D.1 • 12/10
HARRIS CORPORATION
5-3
5 Service
di
ital
Module Servicing
Most modules consist of two assemblies: a face-
plate/switchboard assembly and a Main PCA. A
Connector PCA may also be used for additional
input or logic connectors. Assemblies are field-
replaceable, but they are not field-serviceable. Do
not disassemble the faceplate/switchboard assem-
bly, as these are assembled using a fixture.
Any module not currently in the console’s on-
air signal path can be removed or installed with
the console powered, and on-air, without causing
any audio interruption or noises in the program
audio.
NOTE: Prior to removing any module from the
mainframe, turn off all its bus assignments and
unplug all input, output, and logic cables.
REMOVING MODULES
To remove a module from the mainframe:
1 Open the meter panel.
2 Use the included hex tool (PRE70-90) to re-
move the two screws located at the top and
bottom of the module, and the grounding
screw located directly below the dip switches.
3 Screw the module pull tool (PRE70-43) into
the grounding screw hole and use the tool to
carefully lift the module out of the mainframe.
NOTE: If you need to replace one of the assem-
blies, please contact Harris Technical Services
Department for further instructions.
grounding
screw
TOOL AND INSTALLATION KITS
A tool kit and an installation kit are shipped
with each new console.
Tool Kit
The contents and quantities of the 76-2001 Tool
Kit are listed below:
Harris # Description or Use Qty.
38-88 Spare Button Head Screws 12
50-7 AA NiCad Batteries 3
70-126 AMP Crimp Tool 1
70-129 Extraction Tool 1
70-43 Module Pull Tool 1
70-90 Allen driver Hex Tool 1
Installation Kit
The installation kit shipped depends on the
mainframe size ordered:
• BMX
digital
-8: 76-2000-8
• BMX
digital
-14: 76-2000-0
• BMX
digital
-22: 76-2000-1
• BMX
digital
-30: 76-2000-2
• BMX
digital
-38: 76-2000-3
The contents and quantities of the installation
kits are listed below:
Quantities for each BMXdigital framesize
P/N Description -8 -14 -22 -30 -38
14-482 1x3 Housing 40 54 70 86 102
14-484 2x3 Housing 57 80 86 102 118
14-486 2x4 Housing 1 1 1 1 1
14-492 2x7 Housing 7 15 15 19 19
14-494 2x8 Housing 2 2 2 2 2
14-513 2x12 Housing 12 20 36 55 71
15-938-1 Receptacle Contact 900 1250 1534 1966 2366