Revision C • 1/04
HARRIS CORPORATION
2-58
2 Installation
di
g
ital
PP
PP
P
IN #IN #
IN #IN #
IN #
SIGNALSIGNAL
SIGNALSIGNAL
SIGNAL
FUNCTIONFUNCTION
FUNCTIONFUNCTION
FUNCTION
1 LOGIC GROUND Module logic ground.
2 LOGIC GROUND Module logic ground.
3 LOGIC GROUND Module logic ground.
4 STOP COMMAND PULSE Stop command output. N/O contact.
5 START COMMAND PULSE Start command output. N/O contact.
6 LOGIC SUPPLY +5 VDC 5 volt source.
7 ON INPUT (-) Remote On switch input (active low).
8 OFF INPUT (-) Remote Off switch input (active low).
9 COUGH INPUT (-) Remote Cough switch input (active low).
10 LOGIC SUPPLY +5 VDC 5 volt source.
11 LOGIC SUPPLY +5 VDC 5 volt source.
12 LOGIC SUPPLY +5 VDC 5 volt source.
13 COMMANDS COMMON Start/Stop Pulse, Start Sustained common. C contact.
14 TALLIES COMMON Tally relays common connection. C contact.
15 LOGIC ACTIVE TALLY Logic active tally output. N/O contact.
16 OFF TALLY Off tally output. N/O contact.
17 ON TALLY On tally output. N/O contact.
18 ACTIVATE LOGIC INS (+) +VDC to enable external inputs On, Off, Cough, Talkback.
19 RESET (-) Remote Audio Off input (active low).
20 TALK TO C/R INPUT (-) Remote Talkback input (active low).
21 READY (-) Remote Ready input (active low).
22 RESET (+) +VDC to enable Audio Reset function (audio off control).
23 START SUSTAINED Start sustained command output. N/O relay contact.
24 READY (+) +VDC to enable the Ready function (Off lamp control).
Notes: +VDC is between +5 and +40 VDC.
Output tallies/relays can switch voltages up to +60 VDC
Bold indicates connections used in this example.
UNIVERSAL INPUT MODULE MAIN LOGIC CONNECTOR SIGNAL TABLE
(wire insertion
end view)
Mic Remote Control Connection Example
This example shows setting up a Universal Input module as a control room mic using the A input,
with a mic remote control panel connected to the module. Additional information on logic connec-
tions and DIP switch settings for the Universal Input module are on pages 2-18 through 2-23.
UNIVERSAL INPUT MODULE SWITCH SETTINGS
# Switch Name Setting
1 Signal Source OFF
2CR Mute ON
3 Studio 1 Mute OFF
4 Studio 2 Mute OFF
5 External Site Mute OFF
6 Local On, Cough OFF
7 Timer Reset OFF
8 Off Lamp Status ON
Note: ON settings are to the operators left. OFF settings are to the operator’s right.
DS1
# Switch Name Setting
1 Fader Start OFF
2 Start Pulse OFF
3 Dim Control OFF
4 Bypass SRC Converter OFF
5 Mute Setting Control ON
6 Spare Switch OFF
7 Input Level Set OFF
8 Input Level Set OFF
DS2
12
11
10
9
8
7
6
5
4
3
2
1
24
23
22
21
20
19
18
17
16
15
14
13