EasyManua.ls Logo

Harris BMXDIGITAL 99-1200-0 - Page 72

Default Icon
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Revision C • 1/04
HARRIS CORPORATION
2-60
2 Installation
di
g
ital
PP
PP
P
IN #IN #
IN #IN #
IN #
SIGNALSIGNAL
SIGNALSIGNAL
SIGNAL
FUNCTIONFUNCTION
FUNCTIONFUNCTION
FUNCTION
1 LOGIC GROUND Module logic ground.
2 LOGIC GROUND Module logic ground.
3 LOGIC GROUND Module logic ground.
4 STOP COMMAND PULSE Stop command output. N/O contact.
5 START COMMAND PULSE Start command output. N/O contact.
6 LOGIC SUPPLY +5 VDC 5 volt source.
7 ON INPUT (-) Remote On switch input (active low).
8 OFF INPUT (-) Remote Off switch input (active low).
9 CUE INPUT (-) Remote Cue switch input (active low).
10 LOGIC SUPPLY +5 VDC 5 volt source.
11 LOGIC SUPPLY +5 VDC 5 volt source.
12 LOGIC SUPPLY +5 VDC 5 volt source.
13 COMMANDS COMMON Start/Stop Pulse, Start Sustained common. C contact.
14 TALLIES COMMON Tally relays common connection. C contact.
15 CUE TALLY Cue tally output. N/O contact.
16 OFF TALLY Off tally output. N/O contact.
17 ON TALLY On tally output. N/O contact.
18 ACTIVATE LOGIC INS (+) +VDC to enable external inputs On, Off, Cough, Talkback.
19 RESET (-) Remote Audio Off input (active low).
20 REMOTE CUE (-) Activates Cue function (active low).
21 READY (-) Remote Ready input (active low).
22 RESET (+) +VDC to enable Audio Reset function (audio off control).
23 START SUSTAINED Start sustained command output. N/O relay contact.
24 READY (+) +VDC to enable the Ready function (Off lamp control).
Notes: +VDC is between +5 and +40 VDC.
Output tallies/relays can switch voltages up to +60 VDC
Bold indicates connections used in this example.
UNIVERSAL INPUT MODULE MAIN LOGIC CONNECTOR SIGNAL TABLE
(wire insertion
end view)
Basic Peripheral Device Logic Connection Example
This example shows a Universal Input module set up as a line, using the A analog input, to
interface a CD player (Denon DN-951/961 shown in the example). For more information on logic
connections and DIP switch settings for the Universal Input module, see pages 2-18 through 2-23.
UNIVERSAL INPUT MODULE SWITCH SETTINGS
# Switch Name Setting
1 Signal Source OFF
2 CR Mute OFF
3 Studio 1 Mute OFF
4 Studio 2 Mute OFF
5 External Site Mute OFF
6 Local On, Cough OFF
7 Timer Reset ON
8 Off Lamp Status OFF
DS1
# Switch Name Setting
1 Fader Start OFF
2 Start Pulse OFF
3 Start/Stop Pulse OFF
4 Bypass SRC Converter OFF
5 Spare Switch OFF
6 Spare Switch OFF
7 Input Level Set OFF
8 Input Level Set OFF
DS2
12
11
10
9
8
7
6
5
4
3
2
1
24
23
22
21
20
19
18
17
16
15
14
13
Note: ON settings are to the operators left. OFF settings are to the operator’s right.