1 LOGIC GROUND Console logic ground.
2 LOGIC GROUND Console logic ground.
3 LOGIC GROUND Console logic ground.
4 STOP COMMAND PULSE Stop command output. N/O relay contact.
5 START COMMAND PULSE Start command output. N/O relay contact.
6 LOGIC SUPPLY +5 VDC 5 volt source.
7 ON INPUT (-) Remote On switch input (active low).
8 OFF INPUT (-) Remote Off switch input (active low).
9 COUGH INPUT (-) Remote Cough switch input (active low).
10 LOGIC SUPPLY +5 VDC 5 volt source.
11 LOGIC SUPPLY +5 VDC 5 volt source.
12 LOGIC SUPPLY +5 VDC 5 volt source.
13 COMMANDS COMMON Start/Stop Pulse, Start Sustained common. C relay contact.
14 TALLIES COMMON Tally relays common connection. C relay contact.
15 CUE TALLY Cue tally output. N/O relay contact.
16 OFF TALLY Off tally output. N/O relay contact.
17 ON TALLY On tally output. N/O relay contact.
18 ACTIVATE LOGIC INS (+) +VDC to enable external inputs On, Off, Cough, Talkback.
19 RESET (-) Remote Audio Off input (active low).
20 REMOTE CUE (-) Activates the Cue function (active low).
21 READY (-) Remote Ready input (active low).
22 RESET (+) +VDC to enable Audio Reset function (audio off control).
23 START SUSTAINED Start sustained command output. N/O relay contact.
24 READY (+) +VDC to enable the Ready function (Off lamp control) .
Notes: +VDC is between +5 and +40 VDC.
Output relays can switch voltages up to +60 VDC
Bold indicates connections used in this example.
UNIVERSAL INPUT MODULE MAIN LOGIC CONNECTOR SIGNAL TABLE
(wire insertion
end view)
Complex Logic Connection Example
This example shows setting up a Universal Input module (A input, analog) to interface with a
remote logic device, such as an ENCO DADpro. For more information on logic connections and DIP
switch settings for the Universal Input module, see pages 2-18 through 2-23.
UNIVERSAL INPUT MODULE SWITCH SETTINGS
# Switch Name Setting
1 Signal Source OFF
2 CR Mute OFF
3 Studio 1 Mute OFF
4 Studio 2 Mute OFF
5 External Site Mute OFF
6 Local ON Cough OFF
7 Timer Reset ON
8 Ready Lamp Status OFF
DS1
# Switch Name Setting
1 Fader Start OFF
2 Start Pulse OFF
3 Start/Stop Pulse OFF
4 Bypass SRC Converter OFF
5 Spare Switch OFF
6 Spare Switch OFF
7 Input Level Set OFF
8 Input Level Set OFF
DS2
Note: ON settings are to the operator’s left. OFF settings are to the operator’s right.