2-60 888-2629-200 10/6/10
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation
Maxiva ULX COFDM Series
.
Table 2-13 J6, J7 & J8 Customer I/O Board, Remote Status Outputs
Connector
and pin #
Status Output Status Type and Polarity
J6-1 GROUND
J6-2 TRANSMITTER_OFF/ON_STATUS L=ON
H=OFF
J6-3 EXCITER_A/B_ACTIVE_STATUS L= B ON
H= A ON
J6-4 EXCITER_AUTO/MANUAL_STATUS L= AUTO
H= MANUAL
J6-5 GROUND
J6-6 IPA_A/B_ACTIVE_STATUS L= B ON
H= A ON
J6-7 IPA_AUTO/MANUAL_STATUS L= AUTO
H= MANUAL
J6-8 GROUND
J6-9 PUMP_A_B_ACTIVE_STATUS L= A ON
H= B ON
J6-10 PUMP_AUTO/MANUAL_STATUS L= AUTO
H= MANUAL
J6-11 GROUND
J6-12 GROUND
J7-1 GROUND
J7-2 REMOTE_CONTROL_ENABLED/
DISABLED_STATUS
L = Remote ENABLED
H = Remote DISABLED
J7-3 RF SWITCH_A/B_ACTIVE_STATUS L= B ON
H= A ON
J7-4 POWER_CONTROL_AUTO/MANUAL_STATUS L= AUTO
H= MANUAL
J7-5 GROUND
J7-6 RF_MUTED L= RF MUTE ON
H= RF MUTE OFF
J7-7 VSWR_FOLDBACK L= ON
H= OFF
J7-8 GROUND