10/6/10 888-2629-200 2-59
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation
Maxiva ULX COFDM Series
2.15.2 Individual Transmitter Outputs J6, J7& J8
All of the remote status outputs are open collector and will sink 100mA at up to +24Vdc
to provide an indication status is active. The pull up supply voltage for the status
indications can be supplied via J6, J7 & J8 or can be supplied by an external voltage
source. The status output connections are listed in
Table 2-13
J4-4 IPA_AUTO_SELECT Pulsed LOW
J4-5 IPA_MANUAL_SELECT Pulsed LOW
J4-6 GROUND GNDA
J4-7 PUMP_SWITCH_COMMAND Pulsed LOW
J4-8 SPARE
J4-9 PUMP_AUTO_SELECT Pulsed LOW
J4-10 PUMP_MANUAL_SELECT Pulsed LOW
J4-11 GROUND GNDA
J4-12 GROUND GNDA
J5-1 GROUND
J5-2 POWER_CONTROL_AUTO_SELECT Pulsed LOW
J5-3 POWER_CONTROL_MANUAL_SELECT Pulsed LOW
J5-4 GROUND
J5-5 RF_SWITCH_A_SELECTt Pulsed LOW
J5-6 RF_SWITC_B_SELECT Pulsed LOW
J5-7 GROUND
J5-8 NC
J5-9 NC
J5-10 NC
J5-11 NC
J5-12 NC
Table 2-12 J3, J4 & J5, Customer I/O Board, Remote Control Connectors
Connector
and pin #
Function Command Type and
Polarity