10/6/10 888-2629-200 3-23
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
Maxiva ULX COFDM Series
Figure 3-18 System Service Screen (Local)
3.9.3.1 Admin Setup (Local GUI Only)
The Admin screen is accessed by pressing the Admin button shown on the Local GUI
System Service screen shown in figure 3-18. The following parameters are accessed via
the System Service Admin screen.
Login: Allows access as Guest, Operator or Expert. Guest level allows user to view
screens but does not allow adjustments. Operator allows viewing and operational
adjustments. Expert allows viewing, operational and maintenance adjustments.
Local GUI login is admin. Web browser login is admin.
Password: Allows user password entry. There are different login and passwords for
local and web browser GUI usage. The default logins and password from the factory
are:
Local GUI password is harris. Web browser password is harris2009.
Expire: Sets the expiration time for the user access level.
LCD Contrast: The screen contrast can be adjusted dynamically to allow for differ-
ent room lighting by changing the percentage setting.
User (administrators only): This area is used to enter ID’s and passwords for the
various user levels.