2-20 888-2629-200 10/6/10
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation
Maxiva ULX COFDM Series
Figure 2-3 Customer I/O Pump Module and Interlock Connector on Transmitter
!
CAUTION:
MAXIVA ULX SERIES TRANSMITTERS WILL NOT SUPPORT A WATER COOLED
LOAD USING WATER SUPPLIED BY THE ULX PUMP MODULE. ONLY AIR COOLED
TEST LOADS SHOULD BE USED WITH ULX SERIES TRANSMITTERS.
2.6 Transmitter AC Connection
Refer to the Outline Drawing Top View for details on AC inputs to top of cabinet.
NOTE:
AC Connections will be similar across all cabinets in multi-cabinet transmitter
models. Be sure to verify all connections using the correct schematic drawings.
!
WARNING:
DISABLE AND LOCK OUT STATION PRIMARY POWER BEFORE PRIMARY POWER
CABLES ARE CONNECTED TO THE EQUIPMENT.
!
CAUTION:
WHEN CONNECTED TO A 380-415VAC 3 PHASE WYE POWER CONFIGURATION,
NEUTRAL CURRENT CAN BE EQUAL TO OR EXCEED PHASE CURRENTS DUE TO
SWITCH MODE POWER SUPPLY HARMONICS. FINAL INSTALLATION SHALL
ENSURE NEUTRAL CONDUCTOR IS PROPERLY SIZED AND THAT ALL LOCAL
REGULATIONS ARE MET.
Control
Status &
Interlocks