Figure 3-5. Visual Information Screen
Visual Info 1 - This is the 1st of 2 Visual information screens.
This screen is displayed when the METER key is Selected on the
Bargraph Meter screen. This screen displays the Visual informa-
tion within the system such as percent power,forward & reflected
power, VSWR, etc.
Visual Information Screen 1
There are 5 active softkeys on this screen. They are:
NEXT - This key displays the 2nd visual information screen.
This screen has detailed cabinet information pertaining to the
visual system.
AURAL - This key displays the aural information in the system.
SUPPLY - This key will display the Power Supply information
of the transmitter system.
LINE - This key will display the line voltages of the 3 phase input
power.
EXIT - This key will return the user to the Bargraph Meter screen.
NOTE
This and the following screens are shown for a 30kW transmit-
ter. Other power levels may display more or less information de-
pending on configuration.
AURAL INFORMATION ALARM
Power Forward
Reflected Power
VSWR
Chain B Power
AGC Voltage
100 %
1.1:1
6.0 kW
16 W
3000 W
5.77 V
VISUAL SUPPLY LINE EXIT
Chain A Power 3000 W
Reject Load 10 W*
* = Option 20% Aural ONLY
*
*
Figure 3-6. Aural Information Screen
Aural Information - This screen is displayed when the AURAL
key is selected while viewing either VISUAL INFORMATION
screen. This screen displays the Aural information within the
system such as percent power, forward & reflected power,
VSWR, etc.
There are 4 active softkeys on this screen. They are:
VISUAL - This key will display the Visual information screen 1.
SUPPLY - This key will display the Power Supply information
of the transmitter system.
LINE - This key will display the line voltages of the 3 phase input
power.
EXIT - This key will return the user to the Bargraph Meter screen.
3-6 888-2365-001 Rev. B: 1/11/1999
WARNING: Disconnect primary power prior to servicing.