9/15/06 888-2586-001 5-27
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignment
Platinum Z16HD+
Table 5-1 EEPROM U39 Default Parameter Checklist
Platinum Z16HD+ Transmitter
Parameter FM+HD Mode
Default Settings
HD Mode
Default Settings
Forward Factor 0.015393
Reflect Factor 0.000613
CAL Frequency Set to your frequency
(Default = 98MHz)
Operating Frequency Set to your frequency
(Default = 98MHz)
Cal APC Factor 15.15
100% TPO Set 7000W 3500W
Max High Set 7350W 3675W
Max Low Set 3500W 1750W
UPS Setting 3500W 1750W
Low Power Alarm User Configurable
VSWR Foldback 1.30
VSWR Fault 1.70
NOTE: These are typical values: Refer to Factory Test Data for calibration purposes.