2-36 888-2586-001 9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 2 Installation & Initial Turn-On
Figure 2-17 UPS Power Set
[HOME, MORE, CONFIGURATION, B, A, B, then choose the desired modulation format]
2.9 Setting the Low Power Alarm
The transmitter has a low power alarm output for a remote control system. The power
level at which this remote alarm output is triggered, at TB1-13 XMTR_PWR_LO_IND,
is selectable in the Configuration Menus. To set this power level press [HOME, MORE,
CONFIGURATION, B, A, C]. This should take you to the screen in Figure 2-18. Set the
power level at which you want the alarm to become active and press [BACK] to save
changes. For a complete listing of all configurable parameters see “System
Configuration and Calibration” in Section VI, Troubleshooting.
Figure 2-18 Remote Low Power Alarm Set
[HOME, MORE, CONFIGURATION, B, A, C]
2.10 Jumper Settings for Installation of a Harris Exciter
The following is for installing an exciter other than the one (or two) which came with
the transmitter. Any exciter tested and shipped with the transmitter will have already
been configured properly for the transmitter and should not require any jumper changes.
Table 2-3 on page 2-40 includes all relevant jumper placement for the transmitter and
the following exciters: