6-14 888-2586-001 9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 6 Troubleshooting
(f) Fault Reset: Typing f will reset the Fault Strike Status.
(r) RF Mute/Unmute: Typing r will mute (or unmute) the RF depending on the current
state.
(CTRL-z) Lock/Unlock: This will allow the user to unlock the current configuration
settings so that they can be adjusted. The state of this lock is given next to the title
CONFIGURE & SETTINGS” (LOCK) or (UNLOCK).
!
CAUTION:
UNLOCKING, AND THEN MODIFYING THESE CONFIGURATION SETTINGS
INCORRECTLY COULD CAUSE DAMAGE TO THE BOOSTPRO AND/OR ANY
DOWNSTREAM EQUIPMENT (TRANSMITTERS, COMBINERS, REJECT
LOADS, ANTENNAS, ETC.).
FAULTS:
The faults listed on the right side of the screen are self explanatory with the exception of
A-BIT fail and D-BIT fail. A-BIT fail refers to an analog built-in-test that has failed.
This is something that will not come up in normal operation and will not be a concern.
D-BIT fail refers to a digital built-in-test and the same logic applies.