2-8 888-2586-001 9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 2 Installation & Initial Turn-On
2.5.4.4.2 RF IN
The AUX RF OUT (BNC) output from the HDx-FM exciter will need to be connected
to the BoostPro input labeled RF In (BNC).
2.5.4.4.3 CAN
For systems utilizing one or more HDx-FM exciters along with one or more BoostPro
amplifiers, the CAN buss provides the control signal path across a ’blue hose’ cable
between DB-9 connectors labeled CAN on both the HDx-FM and the BoostPro rear
panels.
Special terminating adaptors are provided to allow custom routing of all CAN cables
between DB-9 connectors. These adaptors allow you to route the CAN circuit any way
you like. The only limitation is that only two cables can be attached to any one
connector/adaptor (cable length should not be an issue as maximum cable length for a
CAN connection is 200 feet).
STEP 1 Determine best circuit path - refer to to System Configuration and Cable
Layout drawings in the FlexStar System technical manual (888-2587-
001) and to the Wiring Diagram in schematic package.
STEP 2 Route and cut supplied cable lengths as necessary
NOTE:
Be sure to allow extra cable length to accomodate devices that slide out on rack
rails.
Figure 2-2 CAN Buss Adaptor (Harris #901-0207-271)