1 - High Pass Filter Potentiometer
Variable control of the high pass filter frequency setting from 25 (Hz) to 3.15 (kHz).
2 - Low Pass Filter Potentiometer
Variable control of the low pass filter frequency setting from 160 (Hz) to 20 (kHz).
3 - FLT
Switches the high pass and low pass filters in and out of the 32Classic MS signal path.
4 - EQ
Switches the Equalizer in and out of the 32Classic MS signal path.
5 - LOW Bell
Toggles between shelf mode (default) and bell mode on the LOW band EQ. When bell mode is selected the Q is
proportional to the boost and cut of the LOW band EQ.
6 - LOW Frequency
Variable frequency control for the LOW band EQ from 40 (Hz) to 600 (Hz).