Maintenance 2G40, 2G40 H
54
HATZ
Operator’s Manual
Procedure
Step Activity
1 Check the intake opening (1) - depending on the version - for
coarse contamination such as leaves, heavy dust deposits,
etc., and clean if necessary.
2 Check the dust outlet opening (2) on the cyclone precleaner -
depending on the version - for free airflow and clean if neces-
sary (see chapter 8.2.6 Cleaning the oil bath air filter, page
60).
Dry air filter
Overview
1 Intake opening for combustion air
2 Dust discharge valve
3 Air intake hose
4 Hose clamps
Procedure
Step Activity
1 Check the intake opening (1) for coarse contamination such as
leaves, heavy dust deposits, etc., and clean if necessary.
2 Check that the dust discharge valve (2) is clear. Remove dust
seals by pressing them together.
3 Check the air intake hose (3) and hose clamps (4) for tightness
and good condition.