Operation and use 2L41C, 2M41, 2M41Z
46
HATZ
Operator’s Manual
Step Activity
2 Remove the starting key.
Automatic electrical switch-off with fault storage
This is identified by brief flashing of all indicators after the starting key is
turned to position "I".
NOTICE
If the engine stops again immediately after starting, or stops in-
dependently during operation, this is an indication that a moni-
toring element of the automatic shutoff has been activated.
Procedure
Step Activity
1 Check the indicators (2-4).
After the engine comes to a standstill, the fault will continue to
be displayed by the indicator for approx. another 2 minutes.
2 Then the electrical equipment switches off automatically.
3 Set the starting key to position "0".
4 Turn the starting key back to position "I".
The fault display lights up again.
Remedy the fault before making further starting attempts (see
the chapter 9.1 Troubleshooting, page 84).
The indicator goes out at the next start.
7.7 Refueling
This diesel engine is intended for installation in a machine or for assembly
with other machines to form a machine and does not have its own fuel tank.
Follow the instructions from the manufacturer and comply with the following
safety information.