2L41C, 2M41, 2M41Z Faults
HATZ
91Operator’s Manual
Overview
Pos. Designation
2 Emergency start lever
3 Seal wire
Procedure
Step Activity
1 Check the oil level (see the chapter 7.8 Checking the oil level
and adding oil if necessary, page 47).
2 Remove the capsule hood and the side panel trim (see the
chapter 5 Engine design, page 26).
3 Place a suitable tool, such as a screwdriver, behind the emer-
gency start lever(2) and tear the seal wire(3) between the
emergency start lever and the housing screw with a forceful
jerk.
4 Turn the emergency start lever to the start position.
5 Start the engine (see the chapter 7.5 Starting the engine, page
35).
6 Eliminate the emergency situation within a few seconds.
7 Switch off the engine.
8 Immediately after the emergency operation phase:
Determine the cause of the fault and eliminate it (see the
chapter Troubleshooting).
If necessary, contact your nearest HATZ service station.