What does 'Drive Error! Drive Overload' mean on my Hayward Water Pump?
- RroseginaSep 6, 2025
This error indicates that the motor is drawing excessive current. Check the impeller, diffuser, and shaft seal for any issues.
What does 'Drive Error! Drive Overload' mean on my Hayward Water Pump?
This error indicates that the motor is drawing excessive current. Check the impeller, diffuser, and shaft seal for any issues.
What does 'Drive Error! AC voltage too low' mean on my Hayward Water Pump?
This error indicates that the line voltage has dropped below 185 VAC, causing the pump to stop. Verify that the line voltage is within 10% of the pump's rated voltage.
What does 'Drive Error! AC voltage too high' mean on my Hayward EcoStar SP3400VSP?
This error indicates that the line voltage has risen above 264 VAC, causing the pump to stop. Verify that the line voltage is within 10% of the pump's rated voltage.
What does 'Drive Error! Heatsink overheated' mean on my Hayward Water Pump?
This error indicates that the heatsink of the drive has become overheated. Check the motor airflow path for obstructions and clear them. The pump will restart automatically once the temperature reaches an acceptable limit.
What does 'Drive Error! Drive failed to start' mean on my Hayward Water Pump?
This error indicates that the drive was unable to start the motor. Verify the motor connections to the drive. The drive will attempt to restart the motor 3 times before displaying a pump stall error.
Model | EcoStar SP3400VSP |
---|---|
Type | Variable Speed Pump |
Horsepower | 3.0 HP |
Voltage | 230V |
Energy Efficiency | Energy Star Certified |
Warranty | 3 years |
Control | Digital |
Motor Type | Permanent Magnet |
Speed Settings | Programmable |
Covers general safety, electrical, entrapment, pressure, fire, burn, and installation hazards.
Details electrical specs, voltage, grounding, bonding, and wiring procedures.
Steps for preparing, priming, and starting the pump for operation.
Addresses motor start/operation issues, pump priming, and suction problems.
Solutions for low flow, noisy pump, and understanding drive error codes.