IS26700T Rev-A
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 1
Super Pump
®
700 Series
Owner’s Manual
IMPORTANT SAFETY INSTRUCTIONS
Basic safety precautions s
h
ou
ld
a
l
ways
b
e fo
ll
owe
d
, inc
l
u
d
ing t
h
e fo
ll
owing: Fai
l
ure to fo
ll
ow instructions
can cause severe injury and/or death.
This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for
one of the following signal words and be alert to the potential for personal injury.
WARNING warns about hazards that could cause serious personal injury, death or major property
damage and if ignored presents a potential hazard.
CAUTION warns about hazards that will or can cause minor or moderate personal injury and/or
property damage and if ignored presents a potential hazard. It can also make consumers aware of
actions that are unpredictable and unsafe.
The NOTICE label indicates special instructions that are important but not related to hazards.
Hayward Pool Products
620 Division Street, Elizabeth, NJ 07207
Phone: (908) 355-7995
www.hayward.com
Contents
Product Specific Warnings………2
Introduction……….………………..…4
Installation……….……………..….….7
Shaft Seal Replacement..………..8
Replacement Parts………….……..10
Troubleshooting………….…..…….11
Warranty…………………………………13
Registration ……………………..……15
Question and Answer IconNeed help?

Do you have a question about the Hayward Super Pump 700 Series and is the answer not in the manual?

Hayward Super Pump 700 Series Specifications

General IconGeneral
BrandHayward
ModelSuper Pump 700 Series
CategoryWater Pump
LanguageEnglish

Summary

Important Safety Instructions

Safety Alert Symbol Explanation

Explains the meaning of safety alert symbols (WARNING, CAUTION, NOTICE) and signal words.

Hazardous Conditions and Warnings

Suction Entrapment Hazards

Details various suction entrapment hazards like hair, limb, body, evisceration, and mechanical entrapment.

Preventing Entrapment Hazards

Provides guidelines to reduce suction entrapment risks, including outlet placement and maintenance.

Other Hazard Warnings

Covers hazards from pressure, separation, and components used for child access.

Electrical and Hyperthermia Safety

Electrical Shock Hazards and Precautions

Details risks of electric shock, grounding, bonding, and GFCI requirements for safe operation.

Hyperthermia Risks and Hot Tub Safety

Outlines safety rules for hot tubs, including temperature limits and risks of hyperthermia.

Introduction and Product Overview

Product Benefits

Highlights key features and advantages of the Super Pump® 700 Series.

Product Specifications

Presents the physical dimensions and technical specifications of the pump.

Installation Instructions: Pump Location

Pump Location Guidelines

Provides recommendations for optimal pump placement to ensure efficient operation and longevity.

Installation Instructions: Mounting and Plumbing

Pump Mounting Requirements

Details the necessary base, fastening, and vibration control for pump installation.

Pipe Sizing and Plumbing

Specifies recommended pipe sizes and plumbing techniques for optimal flow and system integrity.

Electrical Installation and Grounding

Voltage and Wiring Options

Explains power source options (115V/230V) and wiring connections for the pump motor.

Grounding and Bonding Procedures

Details essential grounding and bonding practices for electrical safety and preventing shock hazards.

Wiring and Operation

Permanent Circuit Connection

Ensures the pump is permanently connected to a circuit with GFCI protection for safe operation.

Pump Starting and Priming

Provides step-by-step instructions for safely starting and priming the pump.

Maintenance and Storage

Routine Maintenance Tasks

Details cleaning the strainer basket, inspecting seals, and keeping the motor clean.

Storage and Winterization

Guides on preparing the pump for storage or winter, including draining and protection.

Shaft Seal Replacement Procedure

Motor and Impeller Removal

Instructions for removing the motor assembly and impeller to access internal components.

Ceramic Seat Removal and Seal Installation

Details steps for removing the ceramic seat and installing the new shaft seal assembly.

Replacement Parts Identification

Parts Diagram

Visual representation of pump components with reference numbers for easy identification.

Parts Listing and Numbers

A table listing all pump parts with their corresponding reference numbers and model part numbers.

Troubleshooting Guide

Motor Not Starting

Diagnoses common reasons for the motor failing to start and provides solutions.

Motor Shuts Off

Addresses causes of automatic motor shut-off, such as thermal overload, and suggests checks.

Pump Hums But Won't Start

Identifies potential issues like a jammed impeller and how to resolve them.

Pump Priming Issues

Explains common causes for the pump not priming and troubleshooting steps for air leaks or blockages.

Troubleshooting: Low Flow and Noise

Low Flow Conditions

Lists causes for reduced water flow, including clogs, undersized piping, and filter issues.

Noisy Pump Diagnosis

Helps identify sources of pump noise, such as air leaks, vibration, or foreign matter.

Limited Warranty Information

Warranty Coverage and Exclusions

Details the two-year limited warranty, coverage, exclusions, and requirements for service.

Obtaining Warranty Service

Provides instructions on how to contact Hayward for warranty service and authorized centers.

Product Registration

Registration Fields

Fields to record installation date, initial readings, pump, and filter models for record-keeping.

Warranty Card Registration Details

Instructions for completing the warranty card, including purchase details and contact information.

Online Registration

Information on how to register the product warranty online via the Hayward website.