Maintenance
The quartz tube requires cleaning every 12 months to ensure optimal performance.
WARNING: Before cleaning, turn off all power to the HydraPure unit and pool pump. Allow at least 15
minutes for the lamp(s) in the unit to cool. Never remove the electrical enclosure cover without first dis-
connecting the power source from the HydraPure unit. Never remove the HydraPure unit’s cover without
turning off the pump. Before removing lamps, you must wear protective rubber gloves and safety eye
wear. Do not handle a hot lamp or serious burns will occur.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
9
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
2
Remove screws to lid.
4
Disconnect UV lamps
from ballast.
5
Remove spring clip.
3
Remove
single screw
to electrical
enclosure
cover.
1
Turn Off Power to unit or unplug.