29
Clip
HBMA0114-6.3 en
With S24 (S28) ON, the minimum output current is 3 mA. Even with negative
input voltages, this value will not be fallen below. Consequently, a following
device that monitors an interruption of cable, for example, will not respond er-
roneously, or an externally supplied following device will be supplied continu-
ously.
• Gain
Use P22 (P23) to adjust the gain for both output stages in the range
of 0.9 ... 1.1 Instead of the EM002 module, the EM001 module can also be
used. It makes available an additional "10 V/20 mA voltage output. A sepa-
rate zero balance is also possible.
• Zero balance
Since a zero balance is not provided in the EM002 module, the zero point has
to be adjust on the amplifier.