PLC link
164 A4500-1.1 HBM: public WTX120
EW0+
EW1
- 1000
EW2+
EW3
- 1000
EW5 .4-6 3
.7-8 1
13.4.2 Status and error information
Data word EW4 contains additional error and status infor
mation.
EW4 .0 General error Scale error
(e.g. overload/un
derload)
.2-3 Display status 0: In the valid
weighing range
1: Below the mini
mum display value
2: Above the maxi
mum display value
.4 Scale in motion No standstill
.5 Calibration switch
open
Calibration switch is
open
.6 Manual tare Manual tare
.7 Net 0=gross/1=net
.8-9 range Multi-range scale:
0=range 1
1=range 2
2=range 3