SMA18SA-1 SMH18SA-1
Ph-V-Hz
1, 208/230V~, 60Hz 1, 208/230V~, 60Hz
Capacity Btu/h
18000 18000
Input W
1560 1530
Rated current A
6.8 6.7
SEER Btu/w.h
13 13
Capacity Btu/h
—— 18000
Input W
—— 1630
Rated current A
—— 7.1
HSPF W/W
—— 7.7
A
9.2 10.2
A
32.6 32.6
Model
PA150X2CS-3KUU PA150X2CS-3KUU
Type
ROTARY ROTARY
Brand
TOSHIBA TOSHIBA
Capacity Btu/h
15166/15354 15166/15354
Input W
1505/1510 1505/1510
Rated current(RLA) A
7.30/6.65 7.30/6.65
Locked rotor Amp(LRA) A
32.6 32.6
Thermal protector
UP3RE0391-T39 UP3RE0391-T39
Capacitor uF
40
μ
F /370VAC 40
μ
F /370VAC
Refrigerant oil ml
750 750
Model
YDK31-6B YDK31-6B
Brand
WELLING WELLING
Input W
55 55
Capacitor uF
3 3
Speed(hi/mi/lo) r/min
1070/1000/960 1070/1000/960
CFM
620/540/490 620/540/490
dB(A)
45/43/41 45/43/41
Model
YDK53-6KB YDK53-6KB
Brand
WELLING WELLING
Input W
165 165
Capacitor uF
3uF/450V 3uF/450V
Speed r/min
840 840
CFM 1475 1475
dB(A)
59 59
oz 70.6 72.0
PSIG 650 650
Liquid side/ Gas side in
Ф
1/4/
Ф
1/2
Ф1
/4/
Ф
1/2
Max. refrigerant pipe length ft 33 33
Max. difference in level ft 16 16
ºF 63-86 63-86
ºF 65-113 19-113
ft
2
325-430 325-430
Operation temp
Ambient temp
Application area
Outdoor noise level
Refrigerant type R410A
Design pressure
Refrigerant
piping
Indoor air flow (Hi/Mi/Lo)
Indoor noise level (Hi/Mi/Lo)
Outdoor
fan motor
Outdoor air flow
Max. current
Starting current
Compressor
Indoor
fan motor
Model
Power supply
Cooling
Heating
Note:
The noise date is base on semi-anechoic chamber, during actual operation; these values are
normally somewhat different than actual operation.
The above design and specifications are subject to change without prior notice.