Features
DualZoneTechnology.
Turns on lighting when motion is detected.
Automatically turns lighting off.
Bulb Saver™ - Extends bulb life by up to 4x standard
bulbs. Lights bulb to full bright in under 2 seconds.
Patented DualBrite
®
Timer.
Photocell keeps the lighting off during daylight hours.
LED indicates motion was sensed (day or night).
Requirements
Not for use with fluorescent lights.
The light control requires 120-volts AC.
If you want to use Manual Mode, the control must
be wired through a switch.
Install sensor in accordance with local codes.
© 2008 HeathCo LLC 598-1153-02
OPERATION
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
TEST
TEST 1 5 20
ON-TIME
Off 3 6 Dusk to
Dawn
Put ON-TIME switch
on the sensor bottom
to TEST and the Dual-
Brite
®
switch OFF.
DualBrite
®
Timer
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or 20
minutes) then returns to dim mode.
MANUAL MODE
ON-TIME
TEST 1 5 20
... back on.
AUTO
1 Second OFF
then...
Move ON-TIME Switch to
1, 5, or 20 minutes
Mode Switching Summary
Flip light switch off
for one second then
back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
Put the ON-TIME switch in the 1, 5,
or 20 minute position.
Mode: On-Time Works: Day Night
Test
5 Seconds
x x
Auto
1, 5, or 20 Min
x
Manual
To Dawn*
x
Accent
3, 6 Hr, to Dawn
x
DualBrite
®
Replacement
Sensor Head
DualBrite
®
Model SH-5316

Questions and Answers:

Heath Zenith DualBrite Replacement Sensor Head SH-5316 Specifications

General IconGeneral
Product TypeReplacement Sensor Head
BrandHeath Zenith
Model NumberSH-5316
TechnologyDualBrite
Voltage120V AC
Sensor TypeMotion Sensor
Weather ResistanceYes
Light Level AdjustmentYes
Time Delay AdjustmentYes
CompatibilityCompatible with Heath Zenith security lights
Detection RangeUp to 70 ft

Summary

Features

Requirements

OPERATION

TEST Mode Operation

Sets the ON-TIME switch for testing the sensor's motion detection.

AUTO Mode Operation

Configures the ON-TIME switch for automatic operation based on time.

MANUAL MODE Operation

Explains how to activate and use manual mode, primarily at night.

Mode Switching Summary

Provides a visual guide for switching between TEST, AUTO, and MANUAL modes.

DUALBRITE® Timer Function

Details the DUALBRITE® feature for extended low-level lighting after dusk.

INSTALLATION

Wire the Light Control

Step-by-step instructions for wiring the sensor to floodlamps and junction box.

Mount the Light Fixture

Guidance on mounting the fixture and bulb placement for optimal sensor coverage.

TEST AND ADJUSTMENT

Sensor Aiming and Coverage

Adjusting the sensor head for optimal detection range and coverage area.

Setting Time Delay and DUALBRITE®

Configuring the light's ON-TIME delay and DUALBRITE® dimming levels.

DUALZONETM Technology

Explanation of the DUALZONETM feature adding a lower detection zone.

TROUBLESHOOTING GUIDE