Page #1 background imageLoading...
Page #1 background image
© 2007 HeathCo LLC 598-1303-01
Motion Sensor Light
Control
Models 5408 / 5410
Features
Turns on lighting when motion is detected.
Automatically turns lighting off.
Photocell keeps the lighting off during daylight hours.
5410 models have Flash Alert feature (light flashes on
then off twice before turning on full brightness).
Requirements
The light control requires 120-volts AC.
If you want to use Manual Mode, the control must be
wired through a switch.
Some codes require installation by a qualified
electrician.
This product is intended for use with a junction box
marked for use in wet locations.
The backplate has knockouts so the sensor can be
mounted on most junction boxes.
In some applications a universal adaptor plate may
be needed. Adaptors are available at home centers
and electrical supply stores.
Cover
Plate
Light Control
Lamp Holders
Sensor
2 Wire
Connectors
Gasket
4 Mounting
Screws (2 sizes)
This package includes:
OPERATION
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
MANUAL MODE
ON-TIME
10 5 1 TEST
10 5 1 TEST
ON-TIME
TEST
... back on.
AUTO
1 Second
OFF then...
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Move ON-TIME Switch to
1, 5, or 10 minutes
Mode Switching Summary
Flip light switch off
for one second then
back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
As an ENERGY STAR
®
Partner, Heath
®
/Zenith
has determined that this product meets the EN-
ERGY STAR
®
guidelines for energy efficiency.
This product is ENERGY STAR
®
compliant
when used with 120 Watt bulbs.
Mode: On-Time Works: Day Night
Test
5 Seconds x x
Auto
1, 5, or 10 Min x
Manual
Until Dawn* x

Questions and Answers:

Heath Zenith Motion Sensor Light Control 5408 / 5410 Specifications

General IconGeneral
BrandHeath Zenith
ModelMotion Sensor Light Control 5408 / 5410
CategoryHome Safety Product
LanguageEnglish

Summary

Operation Modes

Test Mode

Set ON-TIME switch to TEST for initial setup and calibration.

Auto Mode

Set ON-TIME switch for 1, 5, or 10 minute auto shut-off.

Manual Mode

Use manual mode for night-time operation, toggled via wall switch.

Mode Switching Summary

Summary of how to switch between TEST, AUTO, and MANUAL modes.

Product Features

Installation Requirements

Installation Guide

Wiring the Light Control

Step-by-step guide for connecting wires, routing, and securing the unit.

Mounting Types

Details on Eave Mount and Wall Mount installation procedures.

Flash Alert Deactivation

Testing and Adjustment

Sensor Controls Overview

Locating and understanding the ON-TIME and SENSITIVITY adjustment dials.

Mounting and Sealing

Securing the light control unit and applying sealant for weatherproofing.

Sensor Aiming Guidelines

Product Specifications

Troubleshooting Common Issues

Customer Support Information

Two Year Limited Warranty

Related product manuals