1e at the gate of
0207
A. It should
be
~17,
and associated parts.
33,
R235, and R10. Also check the
cuits.
~
.
·e,
or
associated circuitry,
or
foils.
igh
or
low
at
this time, but pin 13
If it
is
not high -
·e high.
If
it is not high, place the
E switch in the NORM position. Pin
lehigh.
TEST
#7
SWEEP CIRCUITS
Check the wiring
to
deck B of switch SWS.
To
check U205, monitor the voltage at pin 1 while
you short pin
10
to
ground. Pin 1 should go low when
pin 1 0
is
grounded.
Measure the voltage at pin 13
of U201. It should be
high. Short pin 10
of
U205 to ground; pin 13 should
go
low.
Measure the voltage at pin 6
of U203.
It
should be
high.
U202
is
defective.
Measure the voltage at pins
11
and 8 of U202 while
you short pin 1 0
of
U205
to
ground. Pin
11
should
go
high and
pin
8 should
go
low.
U203
is
defective.
Page 34
U202 is defective.