To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Heathkit
wY
YY
av
oe
(Y
Q
Wy
Refer
to
Detail
6-3B
and
usea
strain
relief
to
secure
the
line
cord
in
rear
panel
hole
RF.
Connect
the
free
end
of
the
green
line
cord
wire
to
solder
lug
RA
(S-1).
Make
a
mechanically
secure
connection.
Connect
the
free
end
of
the
white
line
cord
wire
to
terminal
strip
RC
lug
1
(NS).
Connect
the
free
end
of
the
black
line
cord
wire
to
terminal
strip
RC
lug
2
(NS).
Prepare
two
4"
large
black
stranded
wires.
Connect
a
4"
large
black
stranded
wire
from
fuseholder
F1
lug
1
(S-1)
to
terminal
strip
RC
lug
1
($-2).
Make
mechanically
secure
connections.
NOTE:
A
wire
was
previously
soldered
in
the
eyelet
of
this
terminal
strip
lug.
Connect
a
4”
large
black
stranded
wire
from
fuseholder
F2
lug
1
(S-1)
to
terminal
strip
RC
lug
2
(S-2).
Make
mechanically
secure
connections.
NOTE:
A
wire
was
previously
soldered
in
the
eyelet
of
this
terminal
strip
lug.
Prepare
a
4"
medium
black
stranded
wire
and
an
8"
large
black
stranded
wire.
Then
refer
to
inset
drawing
#1
on
the
Pictorial
and
crimp
and
solder
a
push-on
connector
onto
one
end
of
the
two
wires
as
shown.
Push
the
push-on
connector
on
one
end
of
the
black
wires
as
far
as
possible
onto
relay
K2
lug
1.
Then
connect
the
free
end
of
the
4”
medium
black
wire
to
interlock
SW4
lug
2
(S-1)
and
the
free
end
of
the
8”
large
black
wire
to
fuseholder
F2
lug
2
(S-
1).
Make
mechanically
secure
connections.
Prepare
the
following
lengths
of
large
black
stranded
wire:
4"
8"
6"
Refer
to
inset
drawing
#2
on
the
Pictorial
and
crimp
and
solder
a
push-on
connector
onto
one
end
of
each
wire
as
shown.
Push
the
push-on
connector
on
one
end
of
the
4"
large
black
wire
as
far
as
possible
onto
relay
K2
lug,
4
cmcHes)
2
on
Y)
4)
oO
Page
39
2.
Then
connect
the
other
end
of
this
wire
to
the
top
hole
in
the
solder
lug
on
barrier
strip
RD
lug
1
(S-
1).
Make
a
mechanically
secure
connection.
Make
sure
the
wire
that
was
previously
soldered
to
the
bottom
hole
in
this
solder
lug
remains
well
soldered.
Push
the
push-on
connector
on
one
end
of
the
8"
large
black
wire
as
far
as
possible
onto
relay
K2
lug
3.
Then
connect
the
other
end
of
the
wire
to
fuseholder
F1
lug
2
(NS).
Make
a
mechanically
secure
connection.
Push
the
push-on
connector
on
one
end
of
the
6"
large
black
wire
as
far
as
possible
onto
relay
K2
lug
4.
Then
connect
the
other
end
of
this
wire
to
the
bottom
hole
in
the
solder
lug
on
barrier
strip
RD
lug
5
(NS).
Make
a
mechanically
secure
connection.
Prepare
the
following
lengths
of
wire:
4"
small
blue
solid
26"
medium
black
stranded
26"
medium
black
stranded
16"
medium
violet
stranded
16"
medium
violet
stranded
Connect
one
end
of
the
4"
small
blue
solid
wire
to
phono
socket
J3
lug
1
(S-2).
The
other
end
of
this
wire
will
be
connected
later.
Connect
one
end
of
a
26"
medium
black
stranded
wire
to
relay
K2
lug
6
(S-1).
Make
a
mechanically
secure
connection.
Route
the
other
end
of
the
wire
as
shown;
it
will
be
connected
later.
Connect
one
end
of
the
remaining
26”
medium
black
stranded
wire
to
fuseholder
Fl
lug
2
(S-2).
Make
a
mechanically
secure
connection.
Route
the
other
end
of
the
wire
as
shown;
it
will
be
connected
later.
Connect
one
end
of
a
16"
medium
violet
stranded
wire
to
the
bottom
hole
in
the
solder
lug
atbarrier
strip
lug
3
(S-1).
Make
a
mechanically
secure
connection.
Route
the
other
end
of
the
wire
as
shown,
it
will
be
connected
later.
NOTE:
If
you
cannot
connect
the
wire
to
the
solder
lug,
in
thenextstep,
wrap
theend
of
the
wire
around
thebare
portion
of
the
wire
that
is
already
connected
to
the
lug.
Then
solder
the
connection.

Other manuals for Heathkit SB-1000