Disconnect
the
negative
ohmmeter
lead
from
the
ground
post
and
connect
it
to
either
flat
prong
of
the
line
cord
plug.
Connect
the
positive
ohmmeter
lead
to
the
other
flat
prong
of
the
line
cord
plug.
The
ohmmeter
should
indicate
infinity
with
the
PWR/OFF
switch
on
or
off.
If
you
do
not
obtain
the
correct
indication,
check
the
wiring
of
switches
SW3
and
SW4,
relay
K2,
and
barrier
strip
RD.
NOTE:
Due
to
the
way
the
safety
interlock
is
designed,
the
ohmmeter
will
read
infinity
with
the
PWR/OFF
switch
on.
Disconnect
the
ohmmeter
leads
from
the
line
cord
plug.
»
SECONDARY
WIRING
Refer
to
Pictorial
7-2
while
you
make
the
following
tests.
/
“{)
Connect
the
negative
ohmmeter
lead
to
the
ground
post
on
the
rear
of
the
chassis.
Leave
this
lead
connected
to
the
ground
post
until
a
step
directs
you
to
disconnect
it.
Set the
ohmmeter
to
the
R
x
10k
range.
§)
Touch
the
positive
ohmmeter
lead
to
plate
choke
RFC3
lug
1.
The
ohmmeter
should
indicate
200
kQ
or
higher.
NOTE:
It
may
take
several
seconds
for
the
ohmmeter
to
reach
the
indicated
reading.
This
is
due
to
the
charging
effect
of
some
of
the
capacitors
in
the
circuit.
Set
the
ohmmeter
to
the
Rx
10
range.
cS
Touch
the
positive
ohmmeter
lead
to
solder
lug
CN.
The
ohmmeter
should
indicate
between
80
and
120
ohms.
Touch
the
positive
ohmmeter
lead
to
socket
J1
lug
1.
The
ohmmeter
should
indicate
infinity.
Touch
the
positive
ohmmeter
lead
to
socket
J2
lug
1.
The
ohmmeter
should
indicate
infinity.
Now
use
your
finger
to
push
in
on
the
armature
of
relay
K1.
The
ohmmeter
should
indicate
between
80
and
120
ohms.
Set
the
ohmmeter
to
the
R
x
1
range.
Heathkit
O
‘ouch
the
positive
ohmmeter
lead
to
the
top
lead
of
bridge
rectifier
D201
on
the
meter
cir-
cuit
board.
The
ohmmeter
should
indicate
20
Q
or
higher.
Disconnect
the
ohmmeter
leads
from
the
Ampli-
fier.
POWER
ON
Refer
to
Pictorial
following
steps.
7-3.
while
you
perform
the
NOTE:
If
you
wired
your
Amplifier
for
operation
from
a
120-volt
AC
source,
make
sure
that
the
AC
outlet
you
use
has
adequate
wiring
to
handle
the
large
amount
of
current
that
is
drawn
by
the
Ampli-
fier.
.§)
Set
the
top
cover
on
the
chassis
as
shown.
Do
not
remove
the
cover
from
the
chassis
until
a
step
directs
you
to
do
so.
CAUTION:
Even
though
the
Amplifier
has
a
safety
interlock,
there
is
still
a
potential
danger
when
the
line
cord
is
unplugged
and
the
cover
is
removed.
This
is
due
to
the
charge
that
remains
on
the
power
supply
filter
capacitors
for
several
minutes
after
power
is
removed.
Oo
Push
the
PWR/OFF
switch
to
OFF.
Y
Push
the
OPR/STBY
switch
to
STBY.
WY
Turn
the
MULTIMETER
switch
to
HIGH
VOLT-
AGE.
WY
Plug
the
line
cord
plug
into
a
proper
AC
outlet.
Make
sure
the
outlet
matches
the
voltage
you
have
the
Amplifier
wired
for
(120
VAC
or
240
VAC,
nominal).
NOTE:
If
you
do
not
obtain
the
proper
results
in
the
following
steps,
immediately
push
the
PWR/OFF
switch
to
OFF
and
unplug
the
line
cord.
Correct
the
problem
before
you
continue.
{)
Push
the
PWR/OFF
switch
to
PWR.
The
meter
e
lights
should
light
and
the
fan
should
run
(may
be
too
quict
to
hear).
In
addition,
the
Multi-
meter
should
indicate
approximately
3100
volts.