70
OUTPUT
The
tuned
output
circuit
of
the
Amplifier
is
a
pi
network
consisting
of
Plate
capacitor
C27,
load
capacitor
C31,
and
coils
L7,
L8,
and
L9.
Band
switch
SW2E
progressively
shorts
out
the
unused
portions
of
coils
L7
and
L8.
The
coil
turns
in
use
are
tuned
to
resonance
by
Plate
capacitor
C27.
Load
capacitor
C31
is
tuned
to
complete
the
impe-
dance
match
between
the
tube
and
the
load
that
is
connected
to
RF
Out
jack
J2.
On
the
160-meter
band,
fixed
capacitors
C28 and C29
are
switched
in
paral-
lel
with
Load
capacitor
C31
to
provide
the
addition-
al
capacitance
required
on
this
band.
On
the
80
and
40-meter
bands,
capacitor
C29
is
switched
in
paral-
Jel
with
Load
capacitor
C31.
If
a
DC
voltage
is
unintentionally
applied
to
the
plate
output
circuit,
RFC1
will
provide
a
DC
path
to
ground,
thereby
short-circuiting
the
high
voltage
supply,
which
will
blow
the
fuses.
ALC
Circuit
Control
R2
allows
you
to
set
the
ALC
threshold
to
match
your
exciter.
Capacitors
C106
and
C107
form
an
RF
voltage
divider
that
couples
some
of
the
RF
driving voltage
to
diodes
D103
and
D104.
When
the
RF
driving
voltage
exceeds
the
ALC
threshold
voltage,
the
diodes
rectify
the
negative
half
cycles.
Capacitor
C105
filters
and
bypasses
this
voltage,
while
resis-
tor
R103
provides
isolation.
The
negative
voltage
appearing
at
ALC
jack
J4
is
coupled
back
to
the
exciter
to
reduce
its
gain
and
teduce
"flat-topping"
of
voice
peaks
due
to
over-
drive.
Metering
Circuits
GRID
CURRENT
METER
Refer
to
Pictorial
11-1
for
a
simplified
drawing
of
the
grid
current
meter
circuit.
Grid
current
meter
M1
provides
an
indication
of
grid
current
between
0
and
300
milliamperes.
The
grid
current
meter
is
connected
in
parallel
with
shunt
Heathkit
resistor
R203.
The
grid
circuit
return
is
through
relay
K1
lugs
4
and
8,
zener
diode
D2,
to
the
center
tap
of
the
filament
winding
of
power
transformer
T1.
MULTIMETER
HV
(High
Voltage)
Refer
to
Pictorial
11-2
for
a
simplified
drawing
of
the
high
voltage
meter
circuit.
When
you
select
this
function,
resistors
R401
through
R404 form
a_
voltage
divider
to
measure
the
high
voltage.
Resistors
R402
through
R404 form
a
series
multiplier
resistance
for
meter
M2,
while
resistor
R401
formsa
current
shunt
for
the
meter.
IP
(Plate
Current)
Refer
to
Pictorial
11-3
for
a
simplified
drawing
of
the
plate
current
meter
circuit.
When
you
select
this
function,
meter
M2
indicates
the
plate
current
drawn
by
the
tube
between
0
and
700
milliamperes.
It
is
switched
in
parallel
with
resistor
R202
and
measures
the
voltage
drop
across
it.
The
meter
scale
is
calibrated
to
indicate
the
plate
current
by
using
the
fixed
value
of
resistor
R202
and
the
voltage
across
it.
PO
(Power
Output)
Refer
to
Pictorial
114
for
a
simplified
drawing
of
the
power
output
meter
circuit.
Capacitors
C101,
C102,
and
C103
on
the
ALC/power
circuit
board
form
an
RF
voltage
divider
for
a
portion
of
the
RF
output
voltage
to
a
rectifier
circuit
formed
by
diodes
D101
and
D102.
Capacitor
C104
provides
filtering
and
bypassing.
The
resulting
DC
voltage
then
passes
through
resistor
R101
to
the
meter
circuit
board.
The
DC
voltage
coming
from
the
ALC/power
circuit
board
passes
through
control
R204
to
an
amplifier
circuit
formed
by
transistor
Q201
and
its
associated
components.
From
here,
the
current
passes
through
multiplier
resistor
R206
to
the
multimeter,
which
is
calibrated
to
indicate
peak
output
power
between
0
and
2000
watts.
Control
R204
allows
you
to
calibrate
the
meter
for
this
function.