EasyManua.ls Logo

Heathkit SB-101 - Ah.1.67.Hw-101-63: VOX Delay too Short; Ah.1.68.Hw-101-64: Load Control Squeaks with the HW-101-30 Mod Installed; Ah.1.69.Hw-101-65: CW Sidetone Inoperative; Ah.1.70.Hw-101-66: Rotary Switch Detent Change

Heathkit SB-101
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C331 .01 uF ceramic disk
capacitor
21-16
C332 thru C336 470 pF mica capacitor 20-128
R341 thru R346 470 kilo Ohm, 1/2 watt
resistor
1-33
Phase shift circuit board 85-2138-1
“F” connector (3 qty.) 432-734
ah.1.67. HW-101-63: VOX Delay Too Short
AUGUST 12, 1980
HW-101 BULLETIN NO: SSB TRANSCEIVER HW-101-63
Change: C213 from a .2 uF capacitor to a .47 uF capacitor [PN 27-61].
ah.1.68. HW-101-64: Load Control Squeaks with the HW-101-30 Mod Installed
AUGUST 13, 1980
HW-101 BULLETIN NO: SSB TRANSCEIVER HW-101-64
Install a 1/4” flat fiber washer [PN 253-62] between the grommet and the RF cage.
Make this change only to units with the modification described in Bulletin No. HW-101-
30.
ah.1.69. HW-101-65: CW Sidetone Inoperative
AUGUST 21, 1980
HW-101 BULLETIN NO: SSB TRANSCEIVER HW-101-65
This problem will occur only in units that use the phase shift circuit board in place of the
PEC (see Bulletin HW-101-62, dated June 20, 1980).
ah.1.70. HW-101-66: Rotary Switch Detent Change
NOVEMBER 4, 1980
HW-101 BULLETIN NO: SSB TRANSCEIVER HW-101-66
The [PN 266-85] rotary switch detents are being replaced with [PN 266-1116] detents.
The new detents [PN 266-1116] are directly interchangeable with the old ones.
Continue to use the old detents as replacements until Parts Department’s stock is
depleted.
HW-101 Service Bulletins Page 154