17.
RF
OUTPUT CONTROL:
To
lug
RFl
connect
(use
spaghetti)
a
lOK
resistor
lead
(Oll)
(S)
and
the
resistor's
other
lead
goes
to pin 7 of
socket
B (NS).
Connect
a
short
piece
of
wire
from
lug
RF2
(S)
to
lug
A7
(NS).
Fasten
a
piece
of
stiff
bare
wire
to
lug
RF3
(S),
slip
it
through
lug
All
(NS),
pass
the
wire
through
the
nearby
grommet,
and
then
connect
it
to
the
"GROUND"
lug
of
the
RF
"OUT"
jack
(S).
18. ATTENUATOR SWITCH:
To
lug
A.7
connect
a
lead
of a
620-680
resistor
(SG53)
(S)
and
the
resistor's
other
lead
fastens
to
contact
A5
(NS).
Connect
the
other
620-680
resistor
between
lugs
A5
(NS)
and
A3
(NS)
making
certain
that
the
resistor
does
not
protrude
so
that
it
will
interfere
with
slipping
the
chassis
into
the
cabinet.
Connect
a 47
ohm
resistor
(TS29)
be-
tween
solder
lugs
A5
(S)
and
All
(NS).
The
other
47
ohm
resistor
goes
between
contact
lugs
A3
(S)
and
All
(S).
Connect
a
length
of
wire
to
lug
A2
(S)
pass
it
through
the
nearby
grommet,
and
fasten
it
to
the
RF
"OUT"
jack's
"HOT"
lug
(S).
19.
Pass
the
line
cord
(078)
through
the
grommet
in
the
very
back
of
the
chassis,
and knot
the
cord
at
a
convenient
length
so
that
by
pulling
on
the
cord,
a
strain
will
not
be
placed
on
con-
nections
of
cord
to
equipment.
These
connections
are
as
follows: one
lead
of
the
cord
goes
to
the
left
hand
solder
lug
of
the
3
lug
terminal
strip
(S)
and
the
other
lead
connects
to
the
middle
solder
lug
of
the
3
lug
terminal
strip
(S).
THE
TURRET
COIL ASSEMBLY
AND
SUB
CHASSIS WIRING
20. Mount
the
coils
(SG56, SG57, SG58, SG59,
and
SG60) on
the
sub-chassis
as
shown
in
pictorial
3, and
place
a
lockwasher
under
each
of
the
6-32
nuts
used
(see
Fig.
8
for
identification
of
coils.)
Mount
the
4-30
MMF
trimmer
condenser
(SG55)
with
two
4-40
x t
screws
and
nuts.
(Fig.
9)
SG-56
SCJS7
"BAND
A''
"BAND
13
11
SG
58
"BAND'C"
SG
59
''BAND
D"
IDENTIFYING
Cl-\ARACTERISTICS
OF
COILS
Fig.
8
Mount
the
tuning
condenser
(SG40) (keep
the
plates
fully
meshed
to
avoid
damage)
using
three
6-32
x
3/16
screws
and
with a
solder
lug
under
the
screw
furthest
from
the
center
coil.
Use
lockwashers
under
the
two
other
screws.
Fasten
the
band
selector
switch
(SG49)
to
the
sub-chassis
using
a
control
lockwasher
and
nut.
(See
pictorial
3
.)
Mount
the
two
spade
bolts
(G32)
using
on
each
bolt
a
6-32
nut,
and
a
lockwasher
under
the
nut.
(Fig.
10.)
Page
6
SG60
''BAND
E"
D
MOUNTING
OF
TRIMMER
AND
CONNECTIONS
TO
TUNIN6
CONOEN5£R
Fig.
9
~
tkat
lite svb
Chassis
tests
OH..
tt<.e
Shoulder
o.f
tlte
~e
Bolt
(@-@
SPADE
!30LT
ASSEMBLY
Fig.
10

Questions and Answers: