22Model: Slimline
Optional Settings - Feature Table
01
02
03
04
05
06
07
08
09
10
11
12
01
05
07
03
FEATURE
Temperature Format
Switching Differential
Frost Mode
Frost Protection Temperature
Temperature Output Delay
Communications ID No.
Down Temperature Limit
Sensor Selection
Floor Temperature Limit
Optimum Start
Rate of Change
Program Mode
Temperature Format
Output Delay
Up/Down Temperature Limit
Frost Mode
DESCRIPTION
00 = oC, 01 = oF (°C = Default)
01° - 03°C (01°C = Default)
00 = Enabled, 01 = Disabled (00 = Default)
07° - 17°C (12°C = Default)
00 - 15 Minutes (00 = Default)
Not used on this model
00° - 10°C (00 = Default)
00 = Built in Air Sensor
01= Remote Air Sensor
Not used on this model
00 - 03 Hours (00 = Default)
Minutes to raise by 1°C
00 = Non-Programmable
01 = 5/2 Day Programming
02 = 7 Day Programming
00 = °C, 01 = °F (°C = Default)
00 - 15 Minutes (00 = Default)
00
o
- 10
o
C (00 = Default)
00 = Enabled, 01 = Disabled (00 = Default)
SETTING
09
11
Floor Temperature Limit
Rate of Change
Not used on this model
Minutes to raise by 1
o
C