MINIMUM CLEARANCE SEPARATION SPECIFICATIONS
The HEATMOR™ furnace, is certified to be installed outside, away from other buildings. Please observe the
following “Clearance to Combustibles” guidelines. If you have any further questions, which are not addressed
in this Operators Manual, please contact your local dealer for further information.
To HEATMOR™ Stainless Steel Outdoor Furnace Back. 96 Inches
♦ To HEATMOR™ Stainless Steel Outdoor Furnace Top. 18 Inches
To HEATMOR™ Stainless Steel Outdoor Furnace Front. 48 Inches
To HEATMOR™ Stainless Steel Outdoor Furnace Chimney. 96 Inches
To HEATMOR™ Stainless Steel Outdoor Furnace Sides. 6 Inches
♦ Do not store combustible liquids or materials near the furnace.
♦ It is not recommended to install the furnace in any form of building.
Before installing your HEATMOR™ Stainless Steel Outdoor Furnace, if in the United States, always check
any and all applicable state and local regulations and inform your insurance agent.
Before installing your HEATMOR™ Stainless Steel Outdoor Furnace, if in Canada, always check any and all
applicable Provincial and Municipal regulations and inform your insurance agent.
HEATMOR™ Inc. strongly recommends not installing a HEATMOR™ Stainless Steel Outdoor Furnace within
50 feet of any flammable structure.
A HEATMOR™ Stainless Steel Outdoor Furnace should be located with consideration to your neighbors
property and in accordance with local ordinances. Refer to the “Best Burn Practices” for further operating
considerations.
HEATMOR™ Outdoor Furnaces, Model 100 CSS, 200 CSS and 400 DCSS are not designed or certified to be
located in densely populated areas.