79
Too many ashes in
Furnace.
Clean out ashes.
Refer to
“Ash Management and
Removal.”
Water temperature not
being held in the 160-180
degree Fahrenheit range.
Adjust aquastat setting.
Refer to
“Electrical (Water Temperature
Range Control).”
Contact your
Local Dealer.
Excessive Moisture in
Fuel
Use dryer wood
Refer to
“Types of Wood.”
Furnace boils
or rattles
before reaching
maximum
operating
temperature.
Water temperature range
too broad. Reduce Temperature.
Contact your
“Electrical (Water Temperature
Range Control).”
Improper Antifreeze.
Use recommended
Anti-freeze.
Contact your
Local Dealer.
Operating temperature
too high.
Maximum temperature
setting should not
exceed 180 degrees
Fahrenheit.
Refer to
“Electrical (Water Temperature
Range Control).”
Firebox Door
pops or rattles.
Elbow(s) or hoses are
clogged, restricting water
ow through door hoses.
Unclog or replace
elbow(s) or hoses.
Refer to
“Firebox Door Hoses and
Elbows.”
Loading fuel too close to
the rebox door.
Load your fuel away
from the rebox door.
Refer to
“Loading wood into the
HEATMOR™.”
Water temperature range
setting is too wide
Adjust aquastat spread
setting closer
Refer to
“Electrical (Water Temperature
Range Control).”
Very hot burning re.
Mix in some bigger or
less cured wood.
Refer to
“Wood.”
Flash Curtain / Heat
Shield has been
removed.
Install Flash Curtain /
Heat Shield.
Refer to
“Flash Curtain / Heat Shield.”
PROBLEM CAUSE SOLUTION PROCEDURE