87
Over time, (approx. ve
years) with some water
conditions, the sidearm
will clog up with scale
(lime) and restrict or shut
off the ow completely
through the sidearm.
Contact your
Local Dealer.
Improper hook up of the
sidearm exchanger.
Contact your
Local Dealer.
Water in Auger
Tube.
Condensation formation
on cooler steel.
Maintain constant
rebox temperature.
Refer to
“Ash Auger Tube.”
Water
temperature
doesn’t
correspond with
aquastat settings.
Inadequate rate of ow of
water allowing layering of
water temperatures.
Flow should be at
least eight gallons per
minute. Check pump
and installation.
Contact your
Local Dealer.
No contact paste applied
to well of Aquastat
and / or High Limit
Aquastat.
Remove aquastat from
well and apply paste.
Refer to
“Water Temperature
Range Control.”
No contact paste applied
to well of Temperature
Gauge.
Remove Temperature
Gauge from well and
apply paste.
Refer to
“Temperature Gauge.”
Faulty Aquastat. Replace Aquastat.
Refer to
“Water Temperature
Range Control.”
PROBLEM CAUSE SOLUTION PROCEDURE