14
7.0 FAULT FINDING
WARNING: DISCONNECT FROM ALL ELECTRICAL SUPPLIES BEFORE
BEGINNING ANY WORK ON THE WATER HEATER. WATER CONTAINED IN
THE WATER HEATER MAY BE VERY HOT!
The Streamline should give trouble free operation, however if a problem occurs,
the table below should enable most faults to be identied with ease.
Fault nding should be carried out by a competent person and any replacement
parts used should be authorised Heatrea Sadia spare parts.
TABLE 02: FAULT FINDING
SYMPTOM PROBABLE CAUSE ACTION
No water Mains water not turned
on.
Check supply and turn
on.
Insufcient mains
pressure.
Check supply.
Blockage in tap. Clean tap.
No hot water No water in heater. Fill water heater.
Cut out has operated. Reset cut out.
Faulty thermostat. Replace thermostat.
Faulty element. Replace element.
Water is too hot Thermostat is set too
high.
Adjust thermostat.
Faulty thermostat. Replace thermostat.
NOTE: THE WATER IN THE STREAMLINE WILL EXPAND DURING HEATING
CAUSING THE TAP TO DRIP. THIS IS NORMAL AND IS NOT A FAULT WITH
THE STREAMLINE.
7.1 CUT OUT RESET
1. Disconnect the electrical supply.
2. Remove the front cover (see section 3, p6).
3. Depress the red button (see gure 11, p.15).
4. Recommission the Streamline (see section 4, p.10).
5. If the cut out continues to operate contact the Heatrae Sadia Service
Team (see p20 for contact details).