JS07N·JS07·JS08·JS12·JS14
19
Controls
Code
Problem
Action
Limit
Solution
116
Discharge
unit voltage
too high fault
Disable All
Motion
Lithium battery discharge current too low error: check
whether the whole vehicle operates normally. If it still
fails, contact the manufacturer.
117
Discharge
unit voltage
too low fault
Disable All
Motion
Lithium battery cell voltage too low error: check whether
the lithium battery is low and try to charge it. If it still
fails, contact the manufacturer.
118
charge unit
voltage too
high fault
Disable All
Motion
Lithium battery cell voltage too low error: check whether
the lithium battery is low and try to Check current. If it
still fails, contact the manufacturer.
119
Individual
voltage imbal-
ance fault
Disable All
Motion
Lithium battery Individual voltage imbalance error:
check whether the lithium battery is low and try to
Check current. If it still fails, contact the manufacturer.
121
Single unit ex-
tremely low
fault
Disable All
Motion
Restart, If it still fails, contact the manufacturer.
122
Heating relay
adhesion fault
Disable All
Motion
Restart, If it still fails, contact the manufacturer.
123
Heating relay
adhesion fault
Disable All
Motion
Lithium battery cell voltage too high error: check
whether the lithium battery is high and try to discharge
it. If it still fails, contact the manufacturer.
124
Single unit ex-
tremely low
fault
Disable All
Motion
Lithium battery cell voltage too low error: check whether
the lithium battery is low and try to charge it. If it still
fails, contact the manufacturer.
125
high tempera-
ture fault
Disable All
Motion
Lithium battery discharge temperature is too high error:
check whether the lithium battery temperature is too
high and leave it for a period of time. If it still fails, con-
tact the manufacturer.
126
Heating relay
open circuit
fault
Disable All
Motion
Restart, If it still fails, contact the manufacturer.
Fundamental Troubleshooting
Problem Cause Solution
Machine power
off
The equipment has not been
powered on
The key switch is in the OFF position.
The platform controller or the ground
controller emergency stop button is in
the OFF position.
The platform controller is malfunction-
ing or not powered off after download-
ing of a program.
The ground controller is malfunction-
ing or not powered off after download-
ing of a program.
Machine commu-
nication fault
CAN equipment is offline
Inspect whether the leads of the power
supply and communication are in-
serted properly and reliably.
Inspect whether all pins of the Deutsch
plugs for the platform controller and
ground controller connecting cables
are wired according to the drawing.