Personal Safety
Personal Fall Protection
Personal fall protection equipment (PFPE) is
not required when operating this machine. If
PFPE is required by job site or employer rules,
the following shall apply:
All PFPE must comply with applicable govern-
mental regulations and must be inspected and
used in accordance with the manufacturer’s
instructions.
Work Area Safety
Electrocution Hazards
This machine is not electrically insulated and
will not provide protection from contact with or
proximity to electrical current.
Obey all local and governmental regulations
regarding required clearance from electrical
power lines. At a minimum, the required clear-
ance contained in the chart below must be fol-
lowed.
Line Voltage
Required C
learance
0 to 300V Don’t touch
300V to 50KV 3.05 m
50KV to 200KV 4.60 m
200KV to 350KV 6.10m
350KV to 500KV 7.62m
500KV to 750KV 10.67m
750KV to 1000KV
13.72m
Allow for platform movement, electrical line
sway or sag, and beware of strong or gusty
winds.
Keep away from the machine if it contacts en-
ergized power lines. Personnel on the ground
or in the platform must not touch or operate the
machine until energized power lines are shut
off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for weld-
ing