JS07N·JS07·JS08·JS12·JS14
21
Controls
Problem Cause Solution
An overweight
warning appears
when the ma-
chine has no
load
The load has not been cali-
brated
Re-calibrate the load coefficient.
Lift and lower it several times.
The forward
function fails
without a warn-
ing
The forward moving capabil-
ity is malfunctioning
Check whether the PWM plug of the
controller on the lower platform is in-
serted correctly and solidly.
Check whether the connection of the
forward valve is normal.
Inspect whether the platform control-
ler is malfunctioning.
The backward
function fails
without a warn-
ing
The backward moving capa-
bility is malfunctioning
Check whether the PWM plug of the
ground controller is inserted correctly
and solidly.
Check whether the connection of the
forward valve is normal.
Inspect whether the lower platform
controller is malfunctioning.
Tilting warning The level switch is abnormal
The level switch air bubble is not in
the middle position.
The level switch is not connected
properly or firmly.
The ground controller is malfunction-
ing.
No overload
warning
The load has not been cali-
brated or the height is incor-
rect
The sensor has not been calibrated.
The wiring of the load sensor is incor-
rect.
The sensor is not in good condition.
The machine
moves and then
stops intermit-
tently
The battery level is low/the
calibration is incorrect
Re-calibrate the parameters.
The battery is out of power. The elec-
tricity meter only can be referred.
After setting, the
parameters
could not be
saved success-
fully after several
trials.
The storage is abnormal
The parameters cross the line.
The lower platform controller is mal-
functioning.