The function of the Digital Input is user-configurable. The typical
use case is the connection of a door contact, for the purpose of
triggering the passenger counting and video recording functions.
Note that the available options are software-driven and may
change over time.
The APS-R has one usable input (IN0), the APS-R-PoE has two
usable inputs (IN0 and IN1).
Electrical characteristics:
LOW: U
in
< 5.5 V DC, I
in
> 4 mA @ 5 V DC
HIGH: U
in
> 7.5 V DC, I
in
approx. 10 mA @ 24 V DC
galvanically isolated, potential-free
protected against short-circuit and false polarity
The input is also suitable for PLC standard signals with Live Zero
current (4 mA at LOW potential).
A reset of all parameters to the default settings can be performed
in different ways.
Using the user interface
n Go to “Service Tools”
in the user interface. Click “Factory
Reset” to set the parameters to the default settings of the
installed firmware version.
Resetting by Hardware
n Connect the reset pin 1 of the I/O-port with pin 13 for more
than 5 sec. Wait until the status LED has changed from blue to
yellow, the disconnect the reset pin.
Connect the reset pin of the I/O-port with pin 13 for less then 5 sec.
Disconnect the pin while LED illuminated in blue.
The device started in 'Fallback mode' only with a basic emergency
system. You could connect to a simple user interface that allow
you to:
n update the firmware.
n set the IP settings to use DHCP.
n set the parameters to the default settings of the installed firm-
ware version (factory reset).
n download diagnosis data.
n reboot the device.
Digital input
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
+24 V DC
IN0+
GND
IN0-
Fig. 5: Wiring example APS-R
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
+24 V DC
IN0+
GND
IN0-
+24 V DC
IN1+
GND
IN1-
Fig. 6: Wiring example APS-R-PoE
Factory reset
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
Fig. 7: Factory reset
Fallback mode
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
Fig. 8: Reset
Structure and function
Hardware
12 09.06.2017
The reproduction, distribution and utilization of this document as well as the communication of its contents to others
without express authorization is prohibited. Offenders will be held liable for the payment of damages.
All rights reserved in the event of the grant of patent, utility model or design.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hella APS-R and is the answer not in the manual?

Hella APS-R Specifications

General IconGeneral
BrandHella
ModelAPS-R
CategoryAccessories
LanguageEnglish

Related product manuals