EasyManua.ls Logo

Hensel INTEGRA Compact 250 - 9 Maintenance; Replacement of Fuses; Replacement of Modeling Lamp

Hensel INTEGRA Compact 250
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
user manual INTEGRA
HENSEL Studiotechnik 14
9 Maintenance
The INTEGRA compact flash is in need of little maintenance by
the user. The unit should be dry
cleaned from dust from time to
time. Before cleaning separate the unit from the mains outlet.
Caution
:
Under no circumstances is any part of the equipment to be
opened. The equipment is not user serviceable and there is
dangerous high voltage. In the event of difficulty notify your
dealer.
Replacement of fuses
In case of a broken fuse 10 replace fuse only, when the unit is
switched off and separated from the mains outlet.
Attention
: Never repair or bridge fuses.
Only use “fast” fuses with the required values:
Fuse for Code No.
INTEGRA 250 Bi-Voltage/230V operation: 2 AF
INTEGRA 250 Bi-Voltage/115V operation: 4 AF
INTEGRA 500 Bi-Voltage/230V operation: 2 AF
INTEGRA 500 Bi-Voltage/115V operation: 4 AF
Only use fuses in accordance with EN 60127-2/1 and
IEC 127-2/1, respectively. A wrong fuse may cause an
explosion of the halogen modeling lamp.
Before starting up check the provided fuse! Make sure, that
the position of the sliding switch 11 corresponds to the
mains voltage.
Replacement of modeling lamp
Replace modeling lamp only, when unit is switched off and
unplugged from the mains outlet.
Make sure that the modeling lamp is protected by the specified
fuse (see paragraph replacement of fuses above).
For all types of INTEGRA compact flash units only use
max. 300 W / G 6,35 Halogen
as modeling light.
For order please look up the Code No. in the following table.

Related product manuals