16 Parameters
Electrical
Voltage
230V
Basic current
5A
Maximum current
100A
Starting current
≤0.4%Ib(Active)
Frequency
50Hz
Burden in current circuit
<1VA
Burden in voltage circuit
<2W/10VA
Meter life
10 years
Impulse constant
1000imp/kWh
External influence
Protection
IP54(Indoor)
Operating temperature
-40~70
Storage temperature
-40~70
Relative humidity
0~95%(Non Condensing humidity)
Electromagnetic compliance
Fast transient burst
4kV
Surge voltage
4kV
Electrical insulation
impulse voltage
6kV
AC voltage
4kV
Accuracy
Standard Compliance
IEC62052-11 or EN50470-1
IEC62053-21 or EN50470-3
IEC62053-23
Mechanical parameters
Connection type
Direct connection
Network type
1P2W
Terminal configuration
LNNL
Weight of Meter
Approx.0.5kg