VertX EVO series
Before being able to directly connect the device to CredoID software, network and user settings of the HID devices have to be configured through
their graphical user interface. Have the device powered up and Ethernet cable connected to the network/system.
Open a web browser and enter the HID devices IP. By default, every HID controller is configured to respond to a fixed IP address, that is
169.254.242.121. Be sure that your network settings are configured correctly to be able to connect to the controller.
You should be greeted with a login screen. If connecting to the controller for the first time, in the User name field, enter "admin" and leave
the password field empty. If not, enter a configured password.
After authentication is done, you should be presented with Basic setup information window, where network and other settings can be
configured. It is highly recommended to configure a static IP address, for more stable connection. After configuring network settings, set up a
password, if you haven't yet done that and set "Here I am interval" to 120 seconds. After all settings have been configured and saved, closed
down the window.
Tamper, AC Fail, Batt Fail values
To change default HID values of monitoring inputs follow these steps:
After logging into the controller, click "Supplemental Configuration".
Click device or module of which default input state needs to be changed
Use the table below for default ADC values or adjust according to installation requirements.
Device Default
state
HRUL HRLL LRUL LRLL
V1000 N/C 128 0 128 0
N/O 255 128 255 128
Question and Answer IconNeed help?

Do you have a question about the HID VertX EVO Series and is the answer not in the manual?

HID VertX EVO Series Specifications

General IconGeneral
ConnectivityWired
TypeController
CategoryAccess Control
Power Supply12 or 24 VDC
Input Voltage12 or 24 VDC
Communication ProtocolRS-485, TCP/IP
Communication InterfaceRS-485
Reader InterfacesWiegand
ModelVertX EVO V100, VertX EVO V200, VertX EVO V1000

Summary

VertX EVO Series Device Configuration

Basic Network Setup

Configure IP address, subnet mask, default gateway, and DNS server settings for network connectivity.

Central Station Host Communication

Set up parameters for the device to communicate with the central station or host system.

Login Password Management

Set or change the administrator login password for the device interface.

Monitoring Input Configuration

Tamper, AC Fail, Battery Fail Settings

Adjust default monitoring values for tamper, AC power failure, and battery failure inputs.