Thermal Image Scope User Manual
25
Chapter 11 Maintenance
This part introduces the operation of checking device information, upgrading device, and restoring
to defaults, etc.
11.1 View Device Information
Steps
1. Hold to show the menu of device.
2. Select , and press . You can view the device information such as version, and serial No.
11.2 Upgrade Device
Before You Start
Please get the upgrade package first.
Steps
1. Connect the device to your PC with cable.
2. Open the detected disk, copy the upgrade file and paste it to the root directory of the device.
3. Disconnect the device from your PC.
4. Reboot the device.
Result
The device upgrades automatically. The upgrading process will be displayed in the main interface.
11.3 Restore Device
Steps
1. Hold to show the menu of device.
2. Select , and press to restore the device to defaults according to the prompt.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hikmicro THUNDER and is the answer not in the manual?

Hikmicro THUNDER Specifications

General IconGeneral
Pixel Pitch12 μm
Frame Rate50 Hz
ApertureF1.0
Record VideoYes
Capture SnapshotYes
Wi-FiYes
Display0.39" OLED
Magnification1x
Response Waveband8 μm to 14 μm
Lens (Focal Length)19mm
Battery TypeRechargeable Li-ion
Power SupplyDC 5V/2A
Operating Temperature-20°C to +50°C
ReticleYes
Storage Temperature-30 °C to 60 °C (-22 °F to 140 °F)