87
continuously in a period of time, the alarm will be triggered.
Sounder Delay Time
The sounder will be triggered immediately (0s) or after the set time.
Final Door Exit
Only magnetic contacts have this option.
After enabling, when the user use keypads or tag readers to arm:
-Arm With Faults is enabled: During the arming countdown, if the magnetic contact is
triggered and then restored, the arming process will be terminated immediately after
restoring, and the arming is completed.
-Arm With Faults is disabled: If the magnetic contact is triggered and then restored, the
linked area immediately arms the delayed zone.
AM Mode
-Alarm Only When ARM: Anti-masking alarm will be triggered only when the zone is armed.
-Alarm Only When ARM or DISARM: Anti-masking alarm will be triggered whether the zone
is armed or disarmed.
Warning Time Enable
Set the warning time. The warning time countdown will be triggered if the instant zone is
triggered during entry delay or the system not be disarmed after entry delay ends. Local
alarms are generated during the period, but no messages will be pushed.
Swinger Limit Activations
When the number of times the infrared detector is triggered exceeds the set value, the alarm
will no longer be triggered. (Except for anti-masking alarms.).
Dual Zone (Wired Zone)
After enabled, when multi transmitter detects that the entire zone circuit of the local zone
and the extended zone is open circuit, both zones trigger lid opened alarms.
8. If required, link a PIR camera or a camera for the zone.
9. Click Save.
Network Camera
You can add network cameras in the system.
Steps
1. Click Device Management → Mount Device → Network Camera to enter the page.
2. Click +Add to add a camera.
SADP Scanning
Scan all network cameras in the same LAN. A list will pop up after scanning. You can directly
check to add cameras in the list.
3. Click to edit camera parameters.
Video Verification Report
Enable to report alarm video. When the control panel uploads the alarm information, it will