90
takes longer than the Polling failure Times to determine offline to reply, the system will
report faults and the status of device will be shown as offline.
Intercom Service
Enable intercom service. Only one sounder can enable this function.
4. Click Save.
Automation
You can set the parameters of the relay outputs that is enrolled to the AX PRO.
Steps
1. Click Device Management → Mount Device → Automation to enter the page.
– Click to view the main device, channel number, linked areas and linked events.
– Click to view the device status, device temperature, voltage, current, power load,
energy consumed, signal strength and version.
2. Click +Add to add a relay output device.
3. Click to edit the device parameters.
Linked Area
Only enabled areas will be listed.
The newly added peripheral is linked to area 1 by default.
Original Status
Set the device original status to normally open or normally closed.
Tamper Input
When enabled, the tamper-proof function of the device can be detected (if available).
Voltage Protection
When enabled, an exception event will be reported when the voltage is too high or too low.
For Linked Event:
Event Type
Set the status of the device when various events are triggered.
Activation Mode
-Pulse: The device changes to contact status after the trigger and restores to original status
after the set pulse duration.
-Latch: The device changes to the contact status after the trigger and does not restore the
original status.
Contact Status
Set the device status after being triggered.
4. Click Save.