your supplier or to a designated collection point. For more information see:
www.recyclethis.info.
Intended use of the camera
Ex mark:
Hazardous Area Classification: Zone 1, Zone 2, Zone 21, Zone 22.
IP Degree: IP68 (2m, 2h)
Ex Standards:
Special Conditions for Safe Use:
1. Ambient Temperature: -40°C to 60°C.
2. The width of flameproof joint is more than the minimum values specified in
IEC60079-1 standard. If needed, repair of the flameproof joints must only be made in
compliance with the structural specifications provided by the manufacturer. Repairs
must not be made on the basis of values specified in table 4 of IEC60079-1:2014.
3. When installation, the free end of the composite cable should be taken into the inside
of the end-equipment enclosure that is Ex apparatus, or safety area.
4. For type DS-2TD6566TF-*/** Explosion-proof thermal bi-spectrum network
positioning system, When installation, the free end of the composite cable with fiber
should be taken into the inside of the end-equipment enclosure that is Ex apparatus,
or the electrical Ex components (e.g. fiber optic terminal devices), or safety area.
5. DO NOT OPEN WHEN ENERGIZED.
6. USE FASTENERS WITH YIELD STRESS ≥ 450 MPa.