Digital Video Recorder User Manual
88
Figure 5-20 Set Triggered Camera of VCA Alarm
Step 6 Enter Record Schedule Settings interface (Menu> Record> Schedule>Record Schedule), and
then set Event as the record type. For details, see step 2 in Chapter 5.2 Configuring
Recording Schedule.
5.6 Configuring Manual Recording
Purpose
Follow the steps to set parameters for the manual recording. The manual recording is prior to the
scheduled recording.
Step 1 Go to Menu > Manual > Record.
Figure 5-21 Manual Record
Step 2 Enable manual record.
Click the status icon before camera number to change it to .
Or click the status icon of Analog to enable manual record of all channels.
Step 3 Disable manual record.
Click the status icon to change it to .
Or click the status icon of Analog to disable manual record of all channels.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-7208HQHI-K2/P and is the answer not in the manual?

HIKVISION DS-7208HQHI-K2/P Specifications

General IconGeneral
HDD interfaceSerial ATA
Maximum HDD capacity6000 GB
Number of HDDs supported2
Power consumption (typical)60 W
Voltage12 V
Product colorBlack
Audio output channels1.0 channels
Video compression formatsH.264, H.264+, H.265, H.265+
Analog signal format systemNTSC, PAL
BNC input ports1
Video input channels8 channels
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Ethernet LANYes
Ethernet interface typeFast Ethernet
Supported network protocolsTCP/IP, PPPoE, DHCP, Hik-Connect, DNS, DDNS, NTP, SADP, NFS, iSCSI, UPnP, HTTPS, ONVIF
Operating temperature (T-T)-10 - 55 °C
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Weight17480 g
Dimensions (WxDxH)380 x 320 x 48 mm