EasyManuals Logo

HIKVISION DS-96128NI-I24 User Manual

HIKVISION DS-96128NI-I24
241 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #227 background imageLoading...
Page #227 background image
Network Video Recorder User Manual
226
4. Verify the switch is not flow control.
Check the brand, model of the switch connecting IP camera and NVR, and contact with the manufacturer
of the switch to check if it has the function of flow control. If so, please turn it down.
5. Check if the fault is solved by the step 1 to step 4.
If it is solved, finish the process.
If not, please contact the engineer from Hikvision to do the further process.
No monitor connected with the NVR locally and when you manage the IP camera to connect with the
device by web browser remotely, of which the status displays as Connected. And then you connect the
device with the monitor via VGA or HDMI interface and reboot the device, there is black screen with the
mouse cursor.
Connect the NVR with the monitor before startup via VGA or HDMI interface, and manage the IP
camera to connect with the device locally or remotely, the status of IP camera displays as Connect. And
then connect the device with the CVBS, and there is black screen either.
Possible Reasons:
After connecting the IP camera to the NVR, the image is output via the main spot interface by default.
Steps:
1. Enable the output channel.
2. Select “Menu > Configuration > Live View > View”, and select video output interface in the drop-down
list and configure the window you want to view.
The view settings can only be configured by the local operation of NVR.
Different camera orders and window-division modes can be set for different output interfaces
separately, and digits like “D1”and “D2” stands for the channel number, and “X” means the selected
window has no image output.
3. Check if the fault is solved by the above steps.
If it is solved, finish the process.
If not, please contact the engineer from Hikvision to do the further process.
Live view stuck when video output locally.
Possible Reasons:
a) Poor network between NVR and IP camera, and there exists packet loss during the transmission.
b) The frame rate has not reached the real-time frame rate.
Steps:
1. Verify the network between NVR and IP camera is connected.
1) When image is stuck, connect the RS-232 ports on PC and the rear panel of NVR with the RS-232
cable.
2) Open the Super Terminal, and execute the command of “ping 192.168.0.0 l 1472 f (the IP address
may change according to the real condition), and check if there exists packet loss.
Simultaneously press Ctrl and C to exit the ping command.
2. Verify the frame rate is real-time frame rate.
Select “Menu > Record > Parameters > Record”, and set the Frame rate to Full Frame.
3. Check if the fault is solved by the above steps.
If it is solved, finish the process.
If not, please contact the engineer from Hikvision to do the further process.

Table of Contents

Other manuals for HIKVISION DS-96128NI-I24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-96128NI-I24 and is the answer not in the manual?

HIKVISION DS-96128NI-I24 Specifications

General IconGeneral
Audio system2-way
Input bandwidth576 Mbit/s
Output bandwidth512 Mbit/s
Maximum resolution4096 x 2160 pixels
Alarm input channels16
Video input channels128 channels
Alarm output channels8
Supported resolutions4096 x 2160, 3840 x 2160, 2560 x 1440, 1920 x 1080, 1600 x 1200, 1280 x 1024, 1280 x 720, 1024 x 768
Video formats supportedH.264, H.264+, H.265, H.265+, M-JPEG, MPEG4
Number of simultaneously playbacked channels16 channels
Audio RCA inputs1
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet LAN (RJ-45) ports4
Supported network protocolsIPv6, HTTPS, UPnP, SNMP, NTP, SADP, SMTP, NFS, iSCSI, PPPoE, DDNS
Product colorBlack
Rack capacity4U
Rack mountingYes
RAID levels0, 1, 5, 10
HDD capacity- GB
HDD interfaceSATA
Maximum storage capacity10 TB
Number of HDDs installed0
Number of HDDs supported24
AC input voltage100 - 240 V
Power consumption (typical)14 W
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)10 - 90 %
Display typeLCD
Weight and Dimensions IconWeight and Dimensions
Depth528 mm
Width447 mm
Height172 mm
Weight23000 g